FT1000MP  & MarkV Interfaces

 901 Scope

 

Home
Up

 

 

 

Schematic to Interface FT-1000MP with YO-901 Multiscope

Download Schematic Diagram

The YO-901 is a monitoring instrument, originally designed for use with the FT-901DM series of amateur equipment. Here is a schematic to construct an interface that allows the YO-901 to be used with the FT-1000MP. The interface provides both TX and RX monitoring. It is in pdf format and you need Acrobat reader to open it.

The interface is made from parts readily accessible from Radio Shack including the box for less than $5.00.

You also need to construct a cable to connect the TX GND on the back of the FT-1000MP or 1000D to the 11 pin female plug at position ACC 2 on the back of the YO-901. Using a RCA plug into the TX GND connect the center conductor of RCA plug to pin 11 on the 11 pin male plug and connect the outside of the RCA plug to pin 8 (ground from the radio) on the 11 pin male plug.

Courtesy of K3GV




 

 

 

Home | 901 Scope | Amplifiers | Band Select | Cat Cable | Digital | Icom PW1 | OptoCat